    济南卷帘门适用场所及日常维护
    来源:http://www.jnjqjc.com   时间:2014-8-6 11:29:58

    在通常情况下,济南卷帘门大型建筑根据国家消防法的划定配置了消防中心控制系统。当火灾发生时,安装在房顶的烟感传感器(简称烟感)首先接到烟雾信号,同时向中心控制系统报警,消防中心控制系统通过识别后接通火警所在区域的防火卷帘门电源,使火灾区域的防火卷帘按一定的速度下行。当卷帘下行到离地面约1.5米位置时,休止下行,以利于职员的疏散和撤离。防火卷帘门在中间停留一定时间后,再继承下行,直至封闭。防火卷帘门的下行速度和中间停留时间可在安装时进行调整。
    In general, large building configuration of the central fire control system according to the national fire protection law. When the fire occurs, installed in the roof smoke sensor (hereinafter referred to as smoke) first received the smoke signal, and the alarm to the center control system, fire control center control system through the fire doors power recognition on fire area, so that the fire area fire shutter according to certain speed to the downside. When the rolling down from the ground about 1.5 meters position, stop down, to facilitate the evacuation of the staff. A certain time fire shutter door stops in the middle, then inherited down, until the closure. Fire shutter door downlink speeds and intermediate retention time can be adjusted during installation.
      在某些场合,建筑内不配备消防中心控制系统,防火卷帘门仅借助于防火卷帘门的消防控制电器箱实现防火卷帘门的防火划定运行程序。在这种情况下,当火警发生时,烟雾传感器接收的火警信号直接传至防火卷帘门的消防控制电器箱。
    On some occasions, the buildings not equipped with fire central control system, fire designated fire control electrical box for fire shutter doors fire shutter door only with the help of fireproof rolling shutter door operation procedure. In this case, when the fire occurs, the fire control electrical box smog sensor receives the fire alarm signal directly to the fire shutter doors.
      在停电的情况下,只能通过拉动铁链将防火卷帘门放下。防火卷帘门配备的手动,只能单向放下,不能晋升。
    In the case of a power outage, only by pulling the chain fire shutter doors down. Fire doors equipped with manual, only one way down, not promoted.
      防火卷帘门的制作要求较高,即要求整个系统能经受一定时间的1100°左右高温考验,防火卷帘门的耐火时间是防火卷帘门的主要指标。GB14102-2005钢质防火卷帘门通用技术前提中对耐火时间划定了四个防火等级。
    Production of fireproof rolling shutter door is higher, which requires the system can withstand a certain time of around 1100 degrees high temperature test, fire-resistant time fireproof rolling shutter door is the main index of fireproof rolling shutter door. General technology of GB14102-2005 steel fire shutter doors in the premise of the refractory time delineated four fire rating.
      防火卷帘门一般应用于公共场所防火分区和防火隔断平时不作频繁使用,所以要按期的对其进行维护和保养及检修,一旦区域发生火情,防火卷帘才能有效地投入使用。防火卷帘门总结日常维护详细工作应做好以下几点:
    Fire shutter doors are generally used in the public place fire zoning and fire partition don't usually make frequent use, so to schedule maintenance and repair and maintenance of the area, once the fire, fire shutter can effectively put into use. Fire shutter doors up daily maintenance work should be done with the following points:
      1.防火卷帘门应建立按期保养轨制,并做好每樘卷帘的保养记实工作,存案存档。
    1 fire doors should establish regular maintenance system, and do a good job in every shutter maintenance record, record file.
      2.长期不启闭的卷帘半年必需保养一次,内容为消除尘圾,涂刷油漆,对传动部份的链轮滚子链加润滑油生同等。
    2 long term not opening and closing of the shutter half a year must maintain a, content to eliminate the dust, paint, the roller chain sprocket add lubricant to the transmission parts of the equivalent.
      3.检查电器线路和电器设备是否损坏,运转是否正常,能否符合各项指令,如有损坏和不符要求时应立刻检验。
    3 check the electrical lines and electrical equipment is damaged, the operation is normal, can meet all the instructions, such as damage and not to conform to requirements should immediately check.